PERIODIC SERVICE
68
B
Cleaning Air Cleaner Primary Element
1. Remove the air cleaner cover and primary element.
2. Clean the primary element:
(1) When dry dust adheres to the element, blow
compressed air from the inside, turning the
element. Pressure of compressed air must be
under 205 kPa (2.1 kgf/cm , 30 psi).
(2) When carbon or oil adheres to the element, soak
the element in detergent for 15 minutes then wash
it several times in water, rinse with clean water
and dry it naturally. After element is fully dried,
inspect inside of the element with a light and
check if it is damaged or not.
3. Replace air cleaner primary element:
Once yearly or after every sixth cleaning, whichever
comes first.
A
Check to see if the evacuator valve is blocked with
dust.
(1) Grease fitting (Top link)
(2) Grease fitting (Top link bracket)
(3) Grease fitting (Lifting rod)
(1) Grease fitting (Hydraulic lift cylinders pin)
(1) Grease fitting (Steering joint shaft)
(1) Battery terminals
(1) Secondary (safety) element
(2) Primary element
(3) Evacuator valve
(4) Cover