PERIODIC SERVICE
60
B
Checking the fuel and replenishing the
wheel loader
To avoid personal injury or death:
A
Before refueling, always stop the engine, lower
the bucket and attachment to the ground,
release the hydraulic pressure in the hydraulic
system by operating the control levers. Lock all
control levers in neutral, and remove the key.
A
While refueling the wheel loader, smoking,
naked flames and operation of other sources of
ignition are prohibited. Serious personal injury
or death could result.
A
By temperatures over -5 C, use No.2-D diesel fuel,
when temperatures are under -5 C, use No.1-D diesel
fuel.
A
Make sure that the fuel tank is not run empty. Air will
enter the fuel system, and must be purged before
restarting. See "Bleeding the fuel system" in
"SERVICE AS REQUIRED" in "PERIODIC SERVICE"
section.
A
To prevent condensation (water) accumulations in the
fuel tank, fill the fuel into the tank before parking
overnight.
1. Turn the starter switch to the
"RUN"
position.
2. Check the fuel level by the fuel gauge.
3. Open the cover, remove the cap and add the fuel if
necessary.
A
Avoid fuel spills and overfilling the fuel tank.
A
Every time after operation is over, fill the fuel tank fully
and be sure to replace the cap and lock the cover.
A
To open the fuel cap, keep the key inserted.
(1) Fuel gauge
(A) "FULL"
(B) "EMPTY"
(1) Key slot
(2) Cover
(1) Fuel tank cap
Fuel tank capacity
70 L
(1) Starter key
(2) Fuel tank cap
(3) Tank cap cover
Summary of Contents for R065
Page 9: ...CONTENTS SERVICE HOUR METER 89 ...
Page 10: ......
Page 22: ...SAFE OPERATION 12 8 DANGER AND WARNING LABELS ...
Page 23: ... 13 SAFE OPERATION ...
Page 24: ...SAFE OPERATION 14 ...
Page 25: ... 15 SAFE OPERATION ...
Page 26: ...SAFE OPERATION 16 ...
Page 28: ......
Page 30: ...SERVICING OF WHEEL LOADER 2 1 Engine serial No ...