3.1 Operating procedure for Auto Regeneration Mode
3.1.1 Regeneration operating procedure for Auto Regeneration Mode
(1) DPF switch
(2) Regeneration indicator
(3) Parked regeneration indicator
(4) Engine warning indicator
(A) Parked Regeneration side
1. The machine has been set to
“Auto Regeneration Mode”
by default.
switch lamp
“OFF”
“Auto Regeneration Mode”
is activated.
“ON”
“Inhibit Mode”
is activated.
2. When the regeneration indicator starts flashing, a specific amount of PM has built up in the DPF.
Continue to operate the wheel loader, and the regeneration process will begin automatically, make sure that you
are working in a safe area because DPF and exhaust temperature will rise.
NOTE :
• Even if the “Auto Regeneration Mode” is selected, DPF regeneration may not begin because system
requirements have not been satisfied.
• If the engine load is light, regeneration may not begin.
3. When the regeneration conditions are satisfied, the regeneration indicator stops flashing and remains constant
“ON”
.
The regeneration starts automatically whether the wheel loader is in motion or stationary.
4. When the regeneration cycle has completed, the indicator turns
“OFF”
.
NOTE :
• If you press the Inhibit side of the DPF switch during regeneration, the regeneration cycle will be
interrupted. The “Inhibit Mode” is now activated.
• During regeneration, if the engine rpm is lowered, the regeneration cycle may be interrupted.
EXHAUST AFTERTREATMENT DEVICES
OPERATION OF THE ENGINE
R540
55
Summary of Contents for R540
Page 10: ...6 R540 ...
Page 20: ...SAFETY LABELS SAFE OPERATION 16 R540 ...
Page 21: ...SAFE OPERATION R540 17 ...
Page 22: ...SAFE OPERATION 18 R540 ...
Page 23: ...SAFE OPERATION R540 19 ...
Page 24: ... Canopy Cabin SAFE OPERATION 20 R540 ...
Page 25: ... Canopy Cabin Cabin SAFE OPERATION R540 21 ...
Page 26: ... Canopy Cabin SAFE OPERATION 22 R540 ...
Page 28: ...24 R540 ...
Page 146: ...wheel loader scrapping 26 wheel nut checking 102 109 working light switch 36 142 R540 ...