4. Starting system
4.1 Electrical circuit of starting system
When the main switch is turned to the
GLOW
position, the terminal BAT is connected to the terminal ON and AC. The
glow plugs become red-hot, and the preheat indicator lamp also lights on while preheating.
When the main switch is then turned to the
START
position with the safety switches on, the terminal BAT is connected
to the terminals GLOW and ST. Consequently, battery current flows to the starter motor and start the engine.
The main switch automatically returns to the
ON
position, the terminal BAT is connected only to the terminal GLOW,
thereby causing the starting circuit to be opened, stopping the starter motor.
When the main switch turned from the
ON
position to the
OFF
position, the fuel cut-off solenoid moves the fuel
injection pump control rack to the
no fuel injection
position and stops the engine.
The OPC timer equipped is the operator presence control (OPC) system which automatically stops the engine in
approximately one second when operator stands from the seat while shifting the PTO clutch lever and range gear
shift lever.
8. ELECTRICAL SYSTEM
MECHANISM
4. Starting system
8-8
BX1880,BX2380,BX2680,RCK60B-23BX,RCK54-23BX,RCK48-18BX,RCK60D-26BX,RCK54D-26BX
KiSC issued 03, 2019 A
Summary of Contents for ,RCK60B-23BX
Page 19: ...1 INFORMATION KiSC issued 03 2019 A ...
Page 42: ...2 GENERAL KiSC issued 03 2019 A ...
Page 111: ...3 ENGINE KiSC issued 03 2019 A ...
Page 190: ...4 TRANSAXLE KiSC issued 03 2019 A ...
Page 255: ...5 FRONT AXLE KiSC issued 03 2019 A ...
Page 274: ...6 STEERING KiSC issued 03 2019 A ...
Page 291: ...7 HYDRAULIC SYSTEM KiSC issued 03 2019 A ...
Page 344: ...8 ELECTRICAL SYSTEM KiSC issued 03 2019 A ...
Page 399: ...9 MOWER KiSC issued 03 2019 A ...