6.2 Function of IC regulator (3P
connector type)
3P connector is connected to the IC regulator. 3P
connector consists of three leads, L (blue) lead (1), RY
(red / yellow) lead (2), and WR (white / red) lead (3).
L (blue) lead (1) is a lead to transmit the pulse from the
alternator to hour meter and tachometer. When the
main switch is in the
ON
position, the hour meter
indicates operated hours.
While the engine operates, the tachometer indicates
the present engine revolutions.
RY (red / yellow) lead (2) is a lead to chassis.
WG (white / green) lead (3) is a lead to the charge
lamp.
(1) L (blue) lead
(2) RY (red / yellow) lead
(3) WG (white / green) lead
(4) Alternator assembly
(5) IC regulator
(6) Load
(7) Load
A:
To the battery
B:
To hour meter and tachome-
ter
C:
To main switch
D:
To charge indicator
MECHANISM
6. Charging system
8. ELECTRICAL SYSTEM
BX1880,BX2380,BX2680,RCK60B-23BX,RCK54-23BX,RCK48-18BX,RCK60D-26BX,RCK54D-26BX
8-13
KiSC issued 03, 2019 A
Summary of Contents for ,RCK60B-23BX
Page 19: ...1 INFORMATION KiSC issued 03 2019 A ...
Page 42: ...2 GENERAL KiSC issued 03 2019 A ...
Page 111: ...3 ENGINE KiSC issued 03 2019 A ...
Page 190: ...4 TRANSAXLE KiSC issued 03 2019 A ...
Page 255: ...5 FRONT AXLE KiSC issued 03 2019 A ...
Page 274: ...6 STEERING KiSC issued 03 2019 A ...
Page 291: ...7 HYDRAULIC SYSTEM KiSC issued 03 2019 A ...
Page 344: ...8 ELECTRICAL SYSTEM KiSC issued 03 2019 A ...
Page 399: ...9 MOWER KiSC issued 03 2019 A ...