Operator presence control (OPC)
Symptom
Probable cause and checking
procedure
Solution
Refer-
ence
page
Engine does not stop
1. Solenoid fuse blown (15 A)
Replace
2. Engine stop solenoid relay
damaged
Replace
3. Engine stop solenoid dam-
aged
Replace
4. PTO shift lever switch dam-
aged
Adjust or replace
5. HST pedal switch damaged
Adjust or replace
6. Wiring harness disconnected
or improperly connected (be-
tween key stop solenoid relay
and engine stop solenoid,
between engine stop solenoid re-
lay and battery positive terminal)
Repair or replace
Starter motor does not operate
1. Solenoid fuse blown (15 A)
Replace
2. Engine stop solenoid dam-
aged
Replace
3. Engine stop solenoid relay
damaged
Replace
4. Seat switch or seat turnover
switch damaged
Adjust or replace
5. PTO shift lever switch dam-
aged
Adjust or replace
6. HST pedal switch damaged
Adjust or replace
7. Wiring harness disconnected
or improperly connected (be-
tween key stop solenoid relay
and engine stop solenoid, be-
tween engine stop solenoid relay
and battery positive terminal)
Repair or replace
Engine stops when HST pedal is
pushed in forward or in reverse
1. Wrong wiring of seat switch
and seat turn over switch
Proper wiring
Engine stops suddenly
1. Seat reverse switch
Adjust the switch position
SERVICING
8. ELECTRICAL SYSTEM
BX1880,BX2380,BX2680,RCK60B-23BX,RCK54-23BX,RCK48-18BX,RCK60D-26BX,RCK54D-26BX
8-23
KiSC issued 03, 2019 A
Summary of Contents for ,RCK60B-23BX
Page 19: ...1 INFORMATION KiSC issued 03 2019 A ...
Page 42: ...2 GENERAL KiSC issued 03 2019 A ...
Page 111: ...3 ENGINE KiSC issued 03 2019 A ...
Page 190: ...4 TRANSAXLE KiSC issued 03 2019 A ...
Page 255: ...5 FRONT AXLE KiSC issued 03 2019 A ...
Page 274: ...6 STEERING KiSC issued 03 2019 A ...
Page 291: ...7 HYDRAULIC SYSTEM KiSC issued 03 2019 A ...
Page 344: ...8 ELECTRICAL SYSTEM KiSC issued 03 2019 A ...
Page 399: ...9 MOWER KiSC issued 03 2019 A ...