6.2.5 Checking brush wear
1. Measure the brush length with vernier calipers.
2. If the measurement is less than allowable limit,
replace it.
Brush length
Factory specifi-
cation
10.5 mm
0.413 in.
Allowable limit
8.4 mm
0.331 in.
3. Make sure that the brush moves smoothly.
4. If the brush is damaged, replace it.
6.2.6 Checking rectifier
1. Check the continuity across each diode of rectifier
with resistance range of circuit tester. The rectifier is
normal if the diode in the rectifier conducts in one
direction and does not conduct in the reverse
direction.