• Keep open sparks and flames away from the
battery at all times. Hydrogen gas mixed with
oxygen becomes very explosive.
• Wear eye protection and rubber gloves when
working around battery.
IMPORTANT
• The factory-installed battery is of non-refillable
type. If the battery is weak, charge the battery or
replace it with new one.
• Mishandling the battery shortens the service life
and adds to maintenance costs.
The original battery is maintenance free, but
needs some servicing.
If the battery is weak, the engine will be difficult
to start and the lights will be dim. It is important
to check the battery periodically.
• When exchanging an old battery for new one,
use battery of equal specification in table
below.
Battery
type
Volts
Reserve
capacity
Cold
cranking
amps
Normal
charging
rate
526RMF
12 V
86 min.
560
8.6 A
Maintenance-free,
non-accessible
batteries
are
designed to eliminate the need to add water. Yet the
volume of electrolyte above plates may eventually
become depleted due to abnormal conditions such as
high heat or improper regulator setting. Use a voltmeter
to check the state of charge. See reference chart below
to determine if charging is necessary.
Battery voltage
Reference state of charge
12.6
100% (Full charge)
12.4
75%
12.2
50%
12.0
25%
11.8
0%
Battery charging
DANGER
To avoid serious injury or death:
• When the battery is being activated, hydrogen
and oxygen gases in the battery are extremely
explosive. Keep open sparks and flames away
from the battery at all times, especially when
charging the battery.
WARNING
To avoid serious injury or death:
• When disconnecting the cable from the battery,
start with the negative terminal first. When
connecting the cable to the battery, start with
the positive terminal first.
• Never check battery charge by placing a metal
object across the posts. Use a voltmeter or
hydrometer.
(1) Battery
(2) Clamp
1. To slow charge the battery, connect the battery
positive terminal to the charger positive terminal
and the negative to the negative, then charge for at
least 1 hour at 6.5 amperes.
2. A boost charge is only for emergencies. It will
partially charge the battery at a high rate and in a
short time. When using a boost-charged battery, it
is necessary to recharge the battery as early as
possible. Failure to do this will shorten the battery's
service life.
3. When the specific gravity of electrolyte is between
1.27 and 1.29 the charging is completed.
Battery for storage
1. When storing the machine for a long period,
remove the battery from machine, adjust the
electrolyte to the proper level and store in a dry
place out of direct sunlight.
2. The battery self-discharges while it is stored.
Recharge it once every 3 months in hot seasons
and once every 6 months in cold seasons.
1.5.2 Cleaning air cleaner element
WARNING
To avoid serious injury or death:
• Be sure to stop the engine and remove the key
before cleaning the air cleaner element.
IMPORTANT
• The air cleaner uses a dry element. Never apply
oil to the air cleaner.
• Do not run the engine with filter element
removed.
• Align the arrow marks when reinstalling the
cover. If the cover is improperly fitted, dust
2. GENERAL
CHECK AND MAINTENANCE
1. Periodic service
2-28
BX1880,BX2380,BX2680,RCK60B-23BX,RCK54-23BX,RCK48-18BX,RCK60D-26BX,RCK54D-26BX
KiSC issued 03, 2019 A
Summary of Contents for ,RCK60B-23BX
Page 19: ...1 INFORMATION KiSC issued 03 2019 A ...
Page 42: ...2 GENERAL KiSC issued 03 2019 A ...
Page 111: ...3 ENGINE KiSC issued 03 2019 A ...
Page 190: ...4 TRANSAXLE KiSC issued 03 2019 A ...
Page 255: ...5 FRONT AXLE KiSC issued 03 2019 A ...
Page 274: ...6 STEERING KiSC issued 03 2019 A ...
Page 291: ...7 HYDRAULIC SYSTEM KiSC issued 03 2019 A ...
Page 344: ...8 ELECTRICAL SYSTEM KiSC issued 03 2019 A ...
Page 399: ...9 MOWER KiSC issued 03 2019 A ...