Service - 147
500 Hour
Test Coolant Freeze Protection Level
With engine cool, test coolant freeze protection
level using a hydrometer or refractometer.
Recommended freeze protection level is -34°F
(-37°C). Adjust as needed.
If colder temperatures are expected, consult your
Ditch Witch
®
dealer or coolant supplier.
Use pre-diluted coolant to maintain proper freeze
protection.
Change DEF Filter
Change DEF filter every 500 hours.
To change:
1. Remove DEF filter cover.
2. Pull out DEF filter insert and compensation
body.
3. Insert new DEF filter insert and compensation
body and ensure both are seated correctly.
4. Replace cover and torque to 15-18 ft•lb
(20-25 N•m).
IMPORTANT:
See page 123 for information
on approved coolants.
Summary of Contents for RT105M
Page 1: ...RT105M Operator s Manual Issue 2 0 Original Instruction 053 2943...
Page 7: ...Overview 6 RT105M Operator s Manual About This Manual...
Page 25: ...Safety 24 RT105M Operator s Manual Attachment Safety Alerts...
Page 61: ...Controls 60 RT105M Operator s Manual Battery Disconnect...
Page 65: ...Operation Overview 64 RT105M Operator s Manual Leaving Jobsite...
Page 73: ...Prepare 72 RT105M Operator s Manual Check Supplies and Prepare Equipment...
Page 79: ...Drive 78 RT105M Operator s Manual Shut Down...
Page 87: ...Transport 86 RT105M Operator s Manual Retrieve...
Page 95: ...Backhoe 94 RT105M Operator s Manual Finish Job...
Page 96: ...RT105M Operator s Manual Trench 95 Trench Chapter Contents Set Up 96 Operate 98 Finish Job 100...
Page 165: ...Service 164 RT105M Operator s Manual As Needed...
Page 180: ......
Page 181: ......
Page 182: ...RT105M Operator s Manual Service Record 223 Service Record Service Performed Date Hours...
Page 183: ...Service Record 224 RT105M Operator s Manual Service Performed Date Hours...