PERIODIC SERVICE
82
C
Protected circuit
*
Hydraulic utility valve equipped model
B
Replacing Slow-Blow Fuses
The slow-blow fuses are intended to protect the electrical
cabling. If any of them have blown out, be sure to pinpoint
the cause. Never use any substitute, use only a KUBOTA
genuine part.
C
Replacement procedure
1. Disconnect the negative cable of the battery.
2. Remove the cover and the slow-blow fuse box cover.
3. Pull out the slow-blow fuse.
4. Insert a new slow-blow fuse into the slow-blow fuse
box.
5. Install the slow-blow fuse box cover and the cover.
6. Connect the negative battery cable.
(1) Cover
(2) Fuse box cover
(3) Slow-blow fuse box cover
(1) Fuse puller
(2) Fuse
Fuse No.
Capacity (A)
Protected circuit
1
Slow-blow fuse (50)
Key switch
2
Slow-blow fuse (60)
Alternator
3
15
Head lamp,
Tail lamp, Panel
4
5
Glow lamp
5
10
(Hazard)
6
20
Fan motor
7
15
Eng. Stop
8
15
Alternator, Brake lamp,
Fan motor relay
9
5
Panel,
Eng. Stop control
10
10
12V DC output
11
10
Horn
12
15
(Work light)
13
---
Fuse puller
14
5, 10, 15, 20
Spare
15
*
20
Oil cooler fan motor