61
PERIODIC SERVICE
EVERY 100 HOURS
B
Checking VHT Neutral Spring
1. Park the vehicle on a flat place.
2. Set the parking brake.
3. Shift the range gear shift lever to the "NEUTRAL"
position.
4. Lock the hydraulic lift cylinder lever to the "NEUTRAL"
position with restricting plate.
5. Start the engine.
6. Make sure that the rotation speed of the engine
returns to the idling rotation immediately when taking
the foot off the pedal, after depressing the speed
control pedal several times. If the above does not
occur immediately, consult your local KUBOTA dealer
for this service.
B
Checking VHT Pressure Release
To avoid serious injury:
A
Do not touch muffler or exhaust pipes while
they are hot; severe burns could result.
1. Park the vehicle on a level surface and set the parking
brake.
2. Start the engine and shut it off quickly.
3. Check the points as shown in the figures below.
4. If the result corresponds to either of the following (a) or
(b), consult your local KUBOTA Dealer.
(a) No clearance between rod and link.
(b) The length of the rod is appeared 21.5 mm and
over.
(1) Hydraulic lift cylinder lever
(1) Unload link
(2) Unload valve rod
(L) 21.5 mm and over
(P) The link is contact with the rod.