REGULAR CHECKS AND MAINTENANCE WORK
78
A
To clean up the DPF, a specific machine is required.
Do not attempt to clean it in any other way, such as
disassembling, shaking and heating as toxic
chemicals may be present inside of the DPF.
ANNUAL SERVICING
B
Checking Air-Conditioner Pipes and
Hoses
To avoid personal injury or death:
A
Do not touch the air-conditioner hoses or the
heater with your hand. You may get burned.
1. Check to see that all lines and hose clamps are tight
and not damaged.
2. If hoses and clamps are found worn or damaged,
replace or repair them at once. (Consult your local
KUBOTA Dealer for this service.)
B
Checking Exhaust Manifold (Cracks, Gas,
Leakage and Mounting Screw)
Consult your local KUBOTA Dealer for this service.
B
Checking Intake Air Line for Air Leaks
Consult your local KUBOTA Dealer for this service.
B
Checking Boost Sensor and AFS (Air Flow
Sensor)
Consult your local KUBOTA Dealer for this service.
B
Checking Condition of Diesel Particulate
Filter (DPF) Muffler
Consult your local KUBOTA Dealer for this service.
B
Checking Diesel Particulate Filter (DPF)
Differential Pressure Sensor and Piping
for Gas Leak
Consult your local KUBOTA Dealer for this service.
B
Checking Diesel Particulate Filter (DPF)
Exhaust Gas Temperature Sensor
Consult your local KUBOTA Dealer for this service.
B
Checking EGR Piping for Gas Leak
Consult your local KUBOTA Dealer for this service.
BIENNIAL SERVICING
B
Changing Radiator Coolant
To avoid personal injury or death:
A
When using anti-freeze, use protective clothing
such as rubber gloves (Anti-freeze contains
poison.).
A
If anti-freeze has been swallowed, seek medical
attention at once.
A
When anti-freeze comes in contact with skin or
clothing, wash it off immediately.
A
Do not mix different types of Anti-freeze. The
mixture can produce a chemical reaction
causing harmful substances or vapors.
A
Anti-freeze is extremely flammable and
explosive under certain conditions. Keep fire
and children away from anti-freeze.
A
When draining fluids from the engine, collect
them with a container underneath the engine
body.
A
Do not pour waste onto the ground, down a
drain, or into any water source.
A
Observe all relevant environmental protection
regulations when disposing of anti-freeze.
A
Anti-freeze if swallowed is poisonous to
people, animals and birds.
Park the machine on a firm, flat and level surface, lower
the lift arms to the ground and stop the engine then
remove the key and wait until it has cooled down
completely.
1. Remove the drain plug from the coolant drain hose
and drain coolant completely. Should a recovery tank
be equipped, disconnect the line from the tank floor
and then open the drain shutoff-valve.
2. Return the coolant drain hose to its original position as
illustrated bellow.
3. To clean, rinse the radiator with water.
(1) Coolant drain hose