83
OTHER ADJUSTMENTS AND REPLACEMENTS
B
Slow Blow Fuse
Slow blow fuse is provided to protect the electrical circuits.
If the slow blow fuse is blown, check the electrical circuits
for trouble and then replace with a new compatible slow
blow fuse.
[Open cab model]
[Closed cab model]
C
Replacement procedure
[Bolted slow blow fuse]
1. Disconnect the negative cord of the battery.
2. Remove the slow blow fuse case.
3. Open the slow blow fuse case cap and cover then
remove the bolts and draw out the bolted slow blow
fuse.
(1) Slow blow fuse
(1) Slow blow fuse
Protected circuit
Fuse type
(A)
Main [60A]
Bolted
(B)
Alternator [SSV65: 80A]
[SSV75: 100A]
Bolted
(C)
CRS [30A]
Plug-in
(D)
Glow CAB [60A]
Plug-in
Protected circuit
Fuse type
(A) Main [60A]
Bolted
(B) Alternator [100A]
Bolted
(C) CRS [30A]
Plug-in
(D) Glow CAB [60A]
Plug-in
(1) Slow blow fuse case
(1) Slow blow fuse case cap
(2) Cover
(3) Bolt
(4) Bolted slow blow fuse
Summary of Contents for SSV65
Page 10: ......
Page 20: ...SAFE OPERATION 10 6 DANGER WARNING AND CAUTION LABELS...
Page 21: ...11 SAFE OPERATION...
Page 22: ...SAFE OPERATION 12...
Page 23: ...13 SAFE OPERATION...
Page 24: ...SAFE OPERATION 14...
Page 25: ...15 SAFE OPERATION...