OTHER ADJUSTMENTS AND REPLACEMENTS
56
CHANGING THE BUCKET
To avoid personal injury:
A
When the coupling pins are removed or
installed, chips may come off. Always use
gloves, goggles and a helmet.
A
When the change of the equipment must be
performed with the engine running, always
work as a 2-person team.
One person sits in the operator's seat and the
other works on the machine.
A
Do not use your fingers to center the holes,
since they may be injured or even cut in case of
sudden or uncontrolled movements.
A
Read the manual of the attachment to do a
correct operation safely when other
attachments are installed instead of Kubota
specified bucket.
FUSES
B
Replacing Fuses
1. Remove the cover of the fuse box.
2. Replace the burnt out fuse with a fuse having the same
capacity.
B
Fuse Capacities and Circuits
B
Slow Blow Fuse
Slow blow fuse is provided to protect the electrical circuits.
If the fusible link is blown, check the electrical circuits for
trouble and then replace with a new compatible slow blow
fuse.
(1) Fuse box
5A Meter (+B)
20A Work lamp
5A Starter
5A Room lamp
5A ECU (+B)
30A Engine stop
10A Horn
5A Fuel pump
10A ECU (AC)
5A Relay
15A Auxiliary 1
10A Alternator
15A Auxiliary 2
5A Lever lock
15A Electrical outlet
5A Horn SW
(1) Slow blow fuse (60A)
(2) Slow blow fuse (50A)