EXCAVATOR OPERATION
42
6. Set the maximum flow volume for each AUX port.
Press the switch 4 to move the setting cursor (arrow
mark) to the port 2 position of Thumb port at the right.
7. Press the switch 2 or 3 to preset the maximum flow
volume.
Set the bar to the highest level, and the flow volume
will be maximized.
Set the bar to the lowest level (no bar displayed), and
there will be no oil flow.
Then press the switch 4 to go to the next port, and
make the settings for all the other ports.
A
Some attachments might not be activated even when
the bar level is still somewhat above the lowest
position. Or even when the bars of ports 1 and 2 are
at the same level, the same speed might not be
achieved. This does not indicate a machine problem,
however. Readjust the bar to the optimum level
according to your attachment manual.
A
Suppose that the same attachment is mounted on
another machine. Even if the same flow control setting
is made, the same speed cannot be achieved. Make
an optimum setting on each machine.
(1) Setting cursor (arrow)
(2) Switch 4
(1) AUX 1
(A) "AUX port 1"
(B) "AUX port 2"
(1) Switch 2 (Lower flow volume)
(2) Switch 3 (Higher flow volume)
(3) Switch 4
(A) "MAX. flow volume"
(B) "Output interrupted"
Summary of Contents for U35-4
Page 16: ...SAFE OPERATION 8 6 DANGER WARNING AND CAUTION LABELS ...
Page 17: ... 9 SAFE OPERATION ...
Page 18: ...SAFE OPERATION 10 ...
Page 19: ... 11 SAFE OPERATION ...
Page 20: ...SAFE OPERATION 12 ...
Page 21: ... 13 SAFE OPERATION ...
Page 24: ...DEALER SERVICE 2 1 Engine serial No ...
Page 66: ...44 EXCAVATOR OPERATION ...
Page 114: ...92 LIFTING CAPACITY ...
Page 115: ...93 LIFTING CAPACITY ...