98
W9272-8135-1
05/2020
Operation
After the engine has reached its operating temperature, set the engine speed required for operation:
Turn the potentiometer (1) towards
or
until the required speed is reached.
Turn on AUTO IDLE control (2).
The indicator (3) lights up when the AUTO IDLE control is enabled. The AUTO IDLE control makes sure that the
pre-selected engine speed drops down to idle speed after approx. 4 seconds - provided that no control lever is
being used.
When AUTO IDLE control turn on, the AUTO IDLE indicator (1)
comes up.
When engine speed drops down to idle speed by AUTO IDLE con-
trol, the auto idle indicator (1) flash.
When the hydraulic oil is cold (i. e. in cold-weather conditions), the AUTO IDLE control may experi-
ence problems during the warm-up phase. This does not constitute a failure.