PERIODIC SERVICE
40
B
Checking OPC System
The OPC (Operator Presence Control) system in your
machine are designed to protect you while operating.
Please check these OPC system periodically - daily is
best - to test function of the OPC system before operation.
To avoid serious injury:
A
Do not allow anyone near the machine while
testing.
A
If the machine does not pass one of the
following tests, do not operate the machine.
See your local KUBOTA Dealer.
Test 1
(OPERATOR ON THE SEAT)
1. Start the engine.
2. Do not set the parking brake.
3. Set the PTO switch to "DISENGAGE" (OFF) position.
4. Stand up. (Do not get off the machine.)
5. The engine must shut off.
Test 2
(OPERATOR ON THE SEAT)
1. Start the engine.
2. Do not set the parking brake.
3. Set the PTO switch to "ENGAGE" (ON) position.
4. Stand up. (Do not get off the machine.)
5. The engine must shut off.
A
If the engine remains running in Test 1 through 2,
consult your local KUBOTA Dealer to have the unit
checked before operation.
B
Changing Engine Oil (Z122E, Z125E)
To avoid serious injury:
A
Be sure to stop the engine and remove the key
before changing the oil.
A
Allow engine to cool down sufficiently; oil can
be hot and may cause burns.
1. To change the used oil, unhook the drain hose, direct
the hose down and open the drain valve.
A
The used oil can be drained out more easily if the
engine is warm.
[Z122E, Z125E]
2. Fill with the new oil up to the upper level on the
dipstick.
[Z122E]
(1) Parking brake lever
(2) Motion control lever
(3) Key switch
(4) PTO switch
(5) Seat switch
(1) Drain hose
(2) Drain valve
(3) Hook
(1) Engine oil port
(2) Oil level dipstick
(A) "UPPER LEVEL"
(B) "LOWER LEVEL"