49
PERIODIC SERVICE
1. To slow charge the battery, connect the battery
positive terminal to the charger positive terminal and
the negative to the negative, then charge for at least 1
hour at 6.5 amperes.
2. A boost charge is only for emergencies. It will partially
charge the battery at a high rate and in a short time.
When using a boost-charged battery, it is necessary to
recharge the battery as early as possible.
Failure to do this will shorten the battery's service life.
3. When the specific gravity of electrolyte is between
1.27 and 1.29 the charging is completed.
C
Battery for storage
1. When storing the machine for a long period, remove
the battery from machine, adjust the electrolyte to the
proper level and store in a dry place out of direct
sunlight.
2. The battery self-discharges while it is stored.
Recharge it once every 3 months in hot seasons and
once every 6 months in cold seasons.
B
Adjusting Throttle Cable
[Z122E, Z125E]
1. Move the throttle lever to the "FAST" position.
2. Attempt to pass a pin (A) with a diameter of 3 mm
through the holes indicated.
3. If not possible, loosen the bolt (1) and pull the throttle
lever cable sheath (2) in the direction of the arrow so
that the pin (A) passes through all the required holes
(B). And then tighten the bolt (1).
(1) Battery
(2) Ground cable
(+): Positive terminal
(-): Negative terminal
(1) Throttle lever
(1) Bolt
(2) Throttle lever cable sheath
(A) Pin with a diameter of 3 mm
(B) Hole
(P) "PULL"
Summary of Contents for Z121S-AU
Page 7: ......
Page 12: ... 5 SAFE OPERATION 5 DANGER WARNING AND CAUTION LABELS ...
Page 13: ...SAFE OPERATION 6 ...
Page 14: ... 7 SAFE OPERATION ...