1. To change the used oil, remove the drain hose from
the clamp, direct the hose down and remove the
drain plug.
NOTE :
• The used oil can be drained out more easily
if the engine is warm.
Z231KH-AU, Z251KH-AU
(1) Drain plug
2. Fill with new oil up to the upper level on the dipstick.
Z231KH-AU, Z251KH-AU
(1) Engine oil port
(2) Oil level dipstick
(A) “UPPER LEVEL”
(B) “LOWER LEVEL”
3. To check the oil level:
Remove the dipstick, wipe it clean, insert it and
draw it out again. Check to see that the oil level is
between the 2 notches.
NOTE :
• Do not overfill.
2. Replacing precleaner element
(except Z251BR-AU)
(See Cleaning precleaner element (except
3. Replacing air cleaner element
(Z231BR-AU, Z251BR-AU)
(See Cleaning air cleaner element (
4. Replacing air cleaner element
(Z231KH-AU, Z251KH-AU)
Every 100 hours of operation or annually replace the
paper element.
Z231KH-AU
,
Z251KH-AU
1. Unlatch the cover and remove the air cleaner cover.
2. Remove the air cleaner element and precleaner.
(1) Air cleaner cover
(A) “UNLATCH”
(B) “REMOVE”
3. Remove the precleaner from the paper element.
(1) Air cleaner cover
(2) Air cleaner element
(3) Precleaner
(A) Air intake
4. Replace a dirty, bent, or damaged element with a
genuine part. Handle the new element carefully; do
not use if the sealing surfaces are bent or
damaged.
5. Clean the air cleaner base as required and check
condition.
6. Reinstall the precleaner over the paper element and
install in air intake.
PERIODIC SERVICE
EVERY 100 HOURS
54
Z231BR-AU,Z231KH-AU,Z251BR-AU,Z251KH-AU
Summary of Contents for Z231BR-AU
Page 7: ...4 Z231BR AU Z231KH AU Z251BR AU Z251KH AU ...
Page 13: ...SAFETY LABELS SAFE OPERATION 10 Z231BR AU Z231KH AU Z251BR AU Z251KH AU ...
Page 14: ...SAFE OPERATION Z231BR AU Z231KH AU Z251BR AU Z251KH AU 11 ...
Page 15: ...SAFE OPERATION 12 Z231BR AU Z231KH AU Z251BR AU Z251KH AU ...
Page 16: ...SAFE OPERATION Z231BR AU Z231KH AU Z251BR AU Z251KH AU 13 ...
Page 85: ...wheels 38 82 Z231BR AU Z231KH AU Z251BR AU Z251KH AU ...