BATTERY TROUBLESHOOTING
Symptom (if)
Cause
Remedy
Preventive measure
The starter does not function.
•
Battery overuse, dim
lights.
•
Charge the battery
sufficiently.
•
Charge the battery properly.
•
The battery has not
been recharged.
•
Poor terminal con-
nection.
•
Clean the terminal
and tighten securely.
•
Keep the terminal clean and tight.
Apply grease and treat with anti-cor-
rosives.
•
The battery life has
expired.
•
Replace the battery.
The starter does not function from the
beginning, and lights soon become dim.
•
Insufficient charging.
•
Charge the battery
sufficiently.
•
The battery must be serviced prop-
erly before initial use.
When viewed from the top, the top of the
plates look whitish.
•
The battery was used
with an insufficient
amount of electrolyte.
•
Add distilled water
and charge the bat-
tery.
•
Regularly check the electrolyte lev-
el.
•
The battery was used
too much without re-
charging.
•
Charge the battery
sufficiently.
•
Charge the battery properly.
Recharging is impossible.
•
The battery life has
expired.
•
Replace the battery.
Terminals are severely corroded and
heated up.
•
Poor terminal con-
nection.
•
Clean the terminal
and tighten securely.
•
Keep the terminal clean and tight.
Apply grease and treat with anti-cor-
rosives.
The battery electrolyte level drops rapid-
ly.
•
There is a crack or
pin holes in the elec-
trolytic cells.
•
Replace the battery.
•
Charging
system
trouble.
•
Contact your local
KUBOTA Dealer.
If you have any questions, contact your local KUBOTA dealer.
MACHINE TROUBLESHOOTING
Symptom (if)
Cause
Remedy
The machine operation is not
smooth.
•
The hydrostatic transaxle fluid is insufficient.
•
Fill with oil.
•
The filter is clogged.
•
Replace the filter.
The machine does not move
while the engine is running.
•
The parking brake is on.
•
Release the parking brake.
•
The transaxle fluid level is insufficient.
•
Fill with oil.
The machine moves when the
motion control levers are in the
“NEUTRAL LOCK”
position (op-
erating the engine).
•
The hydrostatic lever linkage is not correctly
adjusted.
•
Ask your dealer for hydrostatic lever linkage
adjustment.
•
The control linkage pivots are sticking.
•
Pull up and lubricate linkage.
All electrical equipment do not
operate.
•
Slow blow fuse blown.
•
Replace the slow blow fuse.
If you have any questions, contact your local KUBOTA dealer.
TROUBLESHOOTING
BATTERY TROUBLESHOOTING
80
Z400
Summary of Contents for Z411
Page 3: ...OPERATOR S MANUAL 1SFRT00108A01 READ AND SAVE THIS MANUAL MODELS Z411 Z421 Z421T ...
Page 9: ...4 Z400 ...
Page 16: ...SAFETY LABELS SAFE OPERATION Z400 11 ...
Page 17: ...SAFE OPERATION 12 Z400 ...
Page 18: ...SAFE OPERATION Z400 13 ...
Page 19: ...SAFE OPERATION 14 Z400 ...
Page 20: ...SAFE OPERATION Z400 15 ...
Page 53: ...PERIODIC SERVICE CHART LABEL MAINTENANCE PERIODIC SERVICE CHART LABEL 48 Z400 ...