45
PERIODIC SERVICE
ENGLISH
B
Checking OPC System
The OPC (Operator Presence Control) system in your
machine are designed to protect you while operating.
Please check these OPC system periodically. It is
recommended to check the OPC system before daily
operation.
To avoid serious injury:
A
Do not allow anyone near the machine while
testing.
A
If the machine does not pass one of the
following tests, do not operate the machine.
See your local KUBOTA Dealer.
Test 1
(OPERATOR ON THE SEAT)
1. Start the engine.
2. Do not set the parking brake.
3. Set the PTO switch to "DISENGAGE" (OFF) position.
4. Stand up. (DO NOT GET OFF THE MACHINE.)
5. The engine must shut off.
Test 2
(OPERATOR ON THE SEAT)
1. Start the engine.
2. Do not set the parking brake.
3. Set the PTO switch to "ENGAGE" (ON) position.
4. Stand up. (DO NOT GET OFF THE MACHINE.)
5. The engine must shut off after 1 second.
A
If the engine remains running in Test 1 or 2, consult
your local KUBOTA Dealer to have the unit checked
before operation.
B
Greasing
To avoid serious injury:
A
Be sure to stop the engine and remove the key
before greasing.
Apply a small amount of multipurpose grease to the
following points every 50 hours:
If you operated the machine in extremely wet and muddy
conditions, lubricate grease fittings more often.
(1) Parking brake pedal
(2) Motion control lever
(3) Key switch
(4) PTO switch
(5) Seat switch
(1) Front axle (LH, RH)
(2) Front wheel (LH, RH)
(1) Seat adjuster
Summary of Contents for Z724X
Page 7: ...CONTENTS ENGLISH INDEX 79 ...
Page 13: ...SAFE OPERATION 6 ENGLISH 5 DANGER WARNING AND CAUTION LABELS ...
Page 14: ... 7 SAFE OPERATION ENGLISH ...
Page 15: ...SAFE OPERATION 8 ENGLISH ...
Page 16: ... 9 SAFE OPERATION ENGLISH ...
Page 19: ...SERVICING OF MACHINE 2 ENGLISH 1 ROPS serial No ...