37
PERIODIC SERVICE
[ZG123S, ZG127S]
Wash and reoil the precleaner
every 25 hours of
operation.
(more often under extremely dusty or dirty
conditions.)
1. Open the door on the blower housing to access the air
cleaner element and precleaner.
2. Unhook the latch and remove the precleaner from the
air cleaner element, or remove as an assembly for
servicing. Make sure the base and the sealing area is
clean before reassembly is performed.
3. Wash the precleaner in warm water with detergent.
Rinse the precleaner thoroughly until all traces of
detergent are eliminated. Squeeze out excess water.
(do not wring.) Allow the precleaner to air dry.
4. Saturate the precleaner with new engine oil.
Squeeze out all excess oil.
5. Reinstall the precleaner over the paper element and
secure with the latch.
6. Close and latch the door.
B
Cleaning Air Cleaner Element (ZG124E,
ZG127E)
Every 100 hours of operation
or
annually
replace the
paper element. Check
every 25 hours of operation
.
(More often under extremely dusty or dirty conditions.)
[ZG124E]
1. Loosen the air cleaner cover knobs and remove the air
cleaner cover.
2. Remove air cleaner element with precleaner.
3. Remove the precleaner from the paper element.
4. Gently tap the paper element to dislodge dirt.
Do not
wash the paper element or use pressurized air
, as
this will damage the element. Replace a dirty, bent, or
damaged element with a genuine part. Handle the new
element carefully; do not use if the sealing surfaces
are bent or damaged.
5. Clean the air cleaner base as required and check
condition.
6. Reinstall the precleaner over the paper air cleaner
element and install it on the base.
(1) Door
(2) Air cleaner element
(3) Latch
(A) "OPEN"
(1) Air cleaner element
(2) Precleaner
(A) Base
(1) Air cleaner cover
(2) Air cleaner cover knob
(1) Air cleaner element
(2) Precleaner
(A) Air intake
(B) Base