PERIODIC SERVICE
40
B
Checking OPC System
The OPC (Operator Presence Control) system in your
machine are designed to protect you while operating.
Please check these OPC system periodically. It is
recommended to check the OPC system before daily
operation.
To avoid personal injury:
A
Do not allow anyone near the machine while
testing.
A
If the machine does not pass one of the
following tests, do not operate the machine.
See your local KUBOTA Dealer.
Test 1
(OPERATOR ON THE SEAT)
1. Start the engine.
2. Do not set the parking brake.
3. Set the PTO switch to "DISENGAGE" (OFF) position.
4. Stand up. (DO NOT GET OFF THE MACHINE.)
5. The engine must shut off.
Test 2
(OPERATOR ON THE SEAT)
1. Start the engine.
2. Do not set the parking brake.
3. Set the PTO switch to "ENGAGE" (ON) position.
4. Stand up. (DO NOT GET OFF THE MACHINE.)
5. The engine must shut off.
A
If the engine remains running in Test 1 through 2,
consult your local KUBOTA Dealer to have the unit
checked before operation.
B
Cleaning Air Cleaner Element (ZG123S,
ZG127S)
Every 100 hours of operation
or
annually
replace the
paper element. Check
every 50 hours of operation
.
(More often under extremely dusty or dirty conditions.)
[ZG123S, ZG127S]
1. Open the door on the blower housing to access the air
cleaner element.
2. Unhook the latch and remove the air cleaner element
and precleaner.
3. Remove the precleaner from the paper element.
4. Gently tap the paper element to dislodge dirt.
Do not
wash the paper element or use pressurized air
, as
this will damage the element. Replace a dirty, bent, or
damaged element with a genuine part. Handle the new
element carefully; do not use if the sealing surfaces
are bent or damaged.
5. Clean the air cleaner base as required and check
condition.
(1) Parking brake lever
(2) Motion control lever
(3) Key switch
(4) PTO switch
(5) Seat switch
(1) Door
(2) Air cleaner element
(3) Latch
(A) "OPEN"
(1) Air cleaner element
(2) Precleaner
(A) Base