KuDos Mechanical
Operating Instructions
■
Before operation:
1. Make sure all parts of the product are clean and rustless, and no loose parts
exist.
2. Check that no leakage occurs while the tool is resting or while the product is
tested without cables
3. Hydraulic pressure should be able to reach 700 bar / 10,000 psi while tested
without cables.
■
During operation:
1.
Do NOT operate the product without the dies or a connector in place.
It
may damage the piston or tool head or the injure the operator.
2. Operation with dies in accordance with the specifications in this handbook is
required. Always keep the fitting centered on the tool die and do not use
over-specification materials.
3. Stop operating immediately in case of any abnormalities. Refer to the
Trouble-Shooting
section of this manual, if:
a) Compression of lugs cannot be implemented.
b) Handle is stuck or unable to be rotated to release pressure.
c) Dies cannot be set in place or removed.
d) Piston is stuck or unable to retract after operation.
■
After operation:
1. Clean the product and ensure that all pieces are in working condition.
2. Apply rust preventive oil on a regular basis.
3. Always store this tool in the case with the cylinder piston fully retracted.
Maintenance
■
Keep the tool head free of dirt and metal chips. Use a lubricant to clean the tool
when necessary.
■
Routine application of rust preventive oil to the product is needed. Avoid bringing the
tool into contact with water or solvents.
■
Do
NOT
keep this product in places with high temperatures, high humidity, or direct
sunlight.
■
Suggested working temperatures
:
-10°C ~ 40°C.
■
Hydraulic fluid temperatures over 65°C might cause damages
to components sealed inside the product.
■
The hydraulic fluid pressure should be adjusted only by
KuDos®
service
representatives.
■
Inform KuDos® authorized distributors in case of any abnormalities or malfunctions of
the product.
■
DO NOT DISASSEMBLE OR ATTEMPT TO REPAIR THIS TOOL.
4
www.ptr.co.th