KFU-
tronic
38
1.051
Acceleration 1
Unit: s
min: 0,1
max.: 1000
Parameter manual:
p. xy
Transfer status:
2
def.: 5
own value (to
be entered!)
Relationship to
parameter:
1,021
1,054
Acceleration 1 is the time that the inverter takes to speed up from 0 Hz to
the high speed.
The acceleration time can be increased through certain circumstances, e.g.
1.051
Acceleration 1
Unit: s
min: 0,1
max.: 1000
Parameter manual:
p. xy
Transfer status:
2
def.: 5
own value (to
be entered!)
Relationship to
parameter:
1,021
1,054
Acceleration 1 is the time that the inverter takes to speed up from 0 Hz to
the high speed.
The acceleration time can be increased through certain circumstances, e.g.
if the drive control is overloaded.
1.052
Deceleration 2
Unit: s
min: 0,1
max.: 1,000
Parameter manual:
p. xy
Transfer status:
2
def.: 10
own value
(to be entered!)
Relationship to
parameter:
1,021
1,054
Deceleration 2 is the time that the inverter takes to brake to 0 Hz from the
high speed (1,021).
If the set deceleration time cannot be reached, the fastest possible decel-
eration time is implemented.
1.053
Acceleration 2
Unit: s
min: 0,1
max.: 1,000
Parameter manual:
p. xy
Transfer status:
2
def.: 10
own value
(to be entered!)
Relationship to
parameter:
1,021
1,054
Acceleration 2 is the time that the inverter takes to speed up from 0 Hz to
the high speed.
The acceleration time can be increased through certain circumstances, e.g.