Mounted field sprayers
124
OMNIS
Machine use
6. Outer discharge
- Position the rinsing tank lever to position 4.
- Remove the quick coupler plug (1).
- Connect the hose to the quick coupler (1).
- Position valves in outer discharge position:
• Suction valve: 2
• Rinsing tank valve (optional): 4
• Accessory valve: G
• Product incorporator lever (optional): E
• Discharge valve: B
- Engage the tractor PTO.
- Wait until the product has fully flown.
- Disengage tractor PTO.
- Place the discharge valve in position A.
- Disconnect hose from the quick coupler (1).
- Reinstall quick coupler plug (1).
Prior to emptying the booms and tank
bottoms, rinse the spraying circuit.
Drain booms and tank bottoms on the treated
cultivation or on another authorized
cultivation, preventing run-off.
In any case, conform with the current
legislation.
Place the machine on level ground.
The outer tank return enables transferring the
liquid.
For models fitted with DPAE regulation (output
proportional to the groundspeed):
- Go to manual mode.
- Shut-off the flow regulation valve.
Summary of Contents for Omnis 1000
Page 1: ...GN007AGB C OPERATOR S MANUAL Mounted field sprayers OMNIS GN007AGB C English 06 2010 ...
Page 2: ......
Page 8: ...Mounted field sprayers 6 OMNIS Identification of the machine 2 Rear view ...
Page 28: ...Mounted field sprayers 26 OMNIS Safety ...
Page 183: ...Limited warranty Mounted field sprayers OMNIS 181 Limited warranty ...
Page 184: ...Mounted field sprayers 182 OMNIS Limited warranty ...
Page 185: ......
Page 186: ......
Page 187: ......
Page 188: ......