3 - 11
3.4. Interfaces for serial communication
The control device is equipped with 3 serial interfaces, two of
which can be used at the same time (RS 232/1 and RS 232/2 or
RS 232/1 and RS 485).
3.4.1. RS 232 (V.24)
The KUAX 680C has two V.24 interface connectors which can
be accessed from above. Use these interfaces to program the de-
vice and to establish the connection for communication with
PCs, user terminals or other machines.
The default configuration of these interfaces (i.e. the configura-
tion without any influence by KUBES modules) is as follows:
protocol
KUBES protocol *)
tranfer rate
9600 baud
data bits
8
parity check
o (odd)
stop bits
1
type of connection
point-to-point
connector
9pin female Sub-D connector
54321
9876
RxD
TxD
Gnd
The connector casing has a conductive connection to the frame
ground (ground connection!). Connect the shield of the connect-
ing cable to the connector casing.
*) To enable communication with devices which run other than
the KUBES protocol, the interfaces can be set to a separate pro-
tocol by means of KUBES modules (see instruction manual E
386 GB "KUBES Modules").