SERVICE MANUAL AS55X
55Xseries_manual_V3.22 (18-08-15)
www.kuhnt.com
93
5.10
GSM access
5.10.1
General
Callback termination mode
For more details about callback termination mode see 1.3.
Here, the callback mode is selected. First you have to activate the callback function in
“GSM access” / “by GSM channel” (see 5.10.2), secondly you have to choose
between the two modes.
If you choose “Reject call for callback after timeout” the incoming call will be rejected
by the AS55X and a callback will be initiated immediately. The second options will be
to “Accept call after timeout”. Then you have to abort your call by yourself to
activate a callback. Therefore you have to determine the phone call within the “call
termination” time that is set in the field below. Otherwise, you can normally call an
extension at your PBX and no callback will be initiated.
Default value:
Reject call for callback after timeout
Call termination / acceptation timeout
After this time the AS55X will reject the incoming call or within this time the incoming
call has to be rejected manually by the call initiator.
If you choose 0 seconds, the call will be rejected immediately.
Adjustment range:
0 … 255 seconds
Default value:
5 seconds
Maximum callback attempts
If a callback to a mobile phone is unsuccessful, further attempts will follow until this
maximum number. If it is not getting successful at all, the processing of a callback will
be aborted.
Adjustment range:
1 … 10
Default value:
3
Callback delay
After the call from a mobile phone is rejected for a callback or after the mobile phone
has aborted his call in order to receive a callback, the AS55X will wait this time before
starting the action.
Adjustment range:
0 … 255 seconds
Default value:
1 second