Service life
The service life of a safety-relevant component begins at the time
of delivery of the component to the customer.
The service life is not affected by whether the component is used
or not, as safety-relevant components are also subject to aging dur-
ing storage.
Danger zone
The danger zone consists of the workspace and the stopping dis-
tances of the manipulator and external axes (optional).
KCP
KUKA Control Panel
Teach pendant for the KR C2/KR C2 edition2005
The KCP has all the operator control and display functions required
for operating and programming the industrial robot.
KUKA smartPAD
see “smartPAD”
KUKA smartPAD-2
see “smartPAD”
Manipulator
The robot arm and the associated electrical installations
Safety zone
The safety zone is situated outside the danger zone.
Safety options
Generic term for options which make it possible to configure addi-
tional safe monitoring functions in addition to the standard safety
functions.
Example: SafeOperation
smartPAD
Programming device for the robot controller
The smartPAD has all the operator control and display functions re-
quired for operating and programming the industrial robot. 2 models
exist:
• smartPAD
• smartPAD-2
In turn, for each model there are variants, e.g. with different lengths
of connecting cables.
For robot controllers of the KR C5 series, only the model “smart-
PAD-2” is used.
For other robot controllers, the designation “KUKA smartPAD” or
“smartPAD” always refers to both models unless an explicit distinc-
tion is made.
Stop category 0
The drives are deactivated immediately and the brakes are applied.
The manipulator and any external axes (optional) perform path-ori-
ented braking.
Note:
This stop category is called STOP 0 in this document.
Stop category 1
The manipulator and any external axes (optional) perform path-
maintaining braking.
• Operating mode T1: the drives are deactivated as soon as the
robot has stopped, but no later than after 680 ms.
• Operating modes T2, AUT (KR C controller), AUT EXT (KR C
controller), EXT (VKR C controller):
The drives are switched off after 1.5 s.
Note:
This stop category is called STOP 1 in this document.
KR IONTEC
MA KR IONTEC V4 | Issued: 11.05.2021
www.kuka.com
| 21/344
Safety
Summary of Contents for IONTEC KR 20 R3100
Page 14: ...KR IONTEC 14 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Introduction...
Page 166: ...KR IONTEC 166 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Planning...
Page 188: ...KR IONTEC 188 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Start up and recommissioning...
Page 310: ...KR IONTEC 310 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Page 340: ...KR IONTEC 340 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 KUKA Service...