may exist. Instruction must be carried out regularly. Instruction is also re-
quired after particular incidents or technical modifications.
Personnel includes:
• System integrator
• Operators, subdivided into:
‒ Start-up, maintenance and service personnel
‒ Operating personnel
‒ Cleaning personnel
System integrator
The industrial robot is safely integrated into a complete system by the sys-
tem integrator.
The system integrator is responsible for the following tasks:
• Installing the industrial robot
• Connecting the industrial robot
• Performing risk assessment
• Implementing the required safety functions and safeguards
• Issuing the EC declaration of conformity
• Attaching the CE mark
• Creating the operating instructions for the system
Operators
The operator must meet the following preconditions:
• The operator must be trained for the work to be carried out.
• Work on the system must only be carried out by qualified personnel.
These are people who, due to their specialist training, knowledge and
experience, and their familiarization with the relevant standards, are
able to assess the work to be carried out and detect any potential
hazards.
3.3
Workspace, safety zone and danger zone
Workspaces are to be restricted to the necessary minimum size. A work-
space must be safeguarded using appropriate safeguards.
The safeguards (e.g. safety gate) must be situated inside the safety zone.
In the case of a stop, the manipulator and external axes (optional) are
braked and come to a stop within the danger zone.
The danger zone consists of the workspace and the stopping distances of
the manipulator and external axes (optional). It must be safeguarded by
means of physical safeguards to prevent danger to persons or the risk of
material damage.
3.4
Overview of protective equipment
The protective equipment of the mechanical component may include:
• Mechanical end stops
• Mechanical axis limitation (optional)
• Release device (optional)
• Brake release device (optional)
KR IONTEC
MA KR IONTEC V4 | Issued: 11.05.2021
www.kuka.com
| 23/344
Safety
Summary of Contents for IONTEC KR 20 R3100
Page 14: ...KR IONTEC 14 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Introduction...
Page 166: ...KR IONTEC 166 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Planning...
Page 188: ...KR IONTEC 188 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Start up and recommissioning...
Page 310: ...KR IONTEC 310 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Page 340: ...KR IONTEC 340 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 KUKA Service...