4
Cover
9.5.3.3
Removing motor A4
Procedure
1. Unscrew 2 M6x12-8.8-A2K Allen screws each from both holders.
Mark the position of cable strap on the cable. Cut off the cable strap
at the first holder.
2. Remove holder from the robot arm.
Carefully cut off cable strap on plug-in connection A6 (far right) with
diagonal cutting pliers.
Remove plug-in connection A6 from the holder and disconnect it.
3. Unscrew 18 M6x35-8.8-A2K Allen screws between the in-line wrist
with arm extension and the arm.
Carefully pull the in-line wrist with arm extension a little way out.
4. Remove grounding from in-line wrist with arm extension. Release and
unplug connectors XM4/XP4 and XM5/XP5 at the right-angle connec-
tors.
5. Remove the in-line wrist with arm extension and set it down on a pre-
pared support.
6. Unscrew 4 M5x14-8.8 Allen screws from motor A4 and pull out the
motor. Do not tilt while removing.
Fig. 9-35: KR 20 R3100 – Removing/installing motors A4 and A5
1
M5x14-8.8-A2K Allen screw (4x per motor)
2
Motor A4
3
Motor A5
4
Sinuous spring 0.25x11.43x15.88 (2x)
5
Connecting shaft R3100 (2x)
6
Arm extension
7
M6x35-8.8-A2K Allen screw with conical spring washer (18x)
KR IONTEC
276/344 |
www.kuka.com
MA KR IONTEC V4 | Issued: 11.05.2021
Repair
Summary of Contents for IONTEC KR 20 R3100
Page 14: ...KR IONTEC 14 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Introduction...
Page 166: ...KR IONTEC 166 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Planning...
Page 188: ...KR IONTEC 188 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Start up and recommissioning...
Page 310: ...KR IONTEC 310 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Page 340: ...KR IONTEC 340 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 KUKA Service...