8.9.2.2
Filling gear unit A5 with gear oil
Procedure
1. Clean both M10x1.0 magnetic screw plugs and check the sealing ele-
ment; exchange magnetic screw plugs if damaged (
>>>
gear unit A5 with gear oil" Page 223
).
2. Remove M10x1.0 oil drain tube.
3. Insert and tighten the lower M10x1.0 magnetic screw plug; M
A
=
7.5 Nm.
4. From the determined quantity of oil, fill the new oil from above using a
funnel.
5. Insert and tighten the upper M10x1.0 magnetic screw plug; M
A
=
7.5 Nm.
6. Check both magnetic screw plugs for leaks.
Fig. 8-19: Filling gear unit A5 with gear oil
1
M10x1.0 magnetic screw plug for venting
2
Funnel
3
Oil filling hose
4
M10x1.0 magnetic screw plug for oil drain hole
8.9.2.3
Concluding work
The following concluding work must be carried out:
• Remove oil residue.
• Visual inspection, check for leaks.
• Run the program in T1 mode and look out for irregularities.
8.9.3
Oil change in A6
Description
The following sections describe the A6 gear oil change for floor-mounted
robots. For ceiling-mounted robots, the procedure is to be applied analo-
gously, but with the drain and filler holes reversed.
KR IONTEC
MA KR IONTEC V4 | Issued: 11.05.2021
www.kuka.com
| 223/344
Maintenance
Summary of Contents for IONTEC KR 20 R3100
Page 14: ...KR IONTEC 14 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Introduction...
Page 166: ...KR IONTEC 166 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Planning...
Page 188: ...KR IONTEC 188 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Start up and recommissioning...
Page 310: ...KR IONTEC 310 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Page 340: ...KR IONTEC 340 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 KUKA Service...