Fig. 8-21: Filling gear unit A6 with gear oil
1
Oil filling hose with funnel
2
M10x1.0 magnetic screw plug for venting
3
M10x1.0 magnetic screw plug for oil drain hole
8.9.3.3
Concluding work
The following concluding work must be carried out:
• Remove oil residue.
• Visual inspection, check for leaks.
• Run the program in T1 mode and look out for irregularities.
8.10
Cleaning the robot
Description
The robot must be cleaned in compliance with the instructions given here
in order to prevent damage. These instructions only refer to the robot.
Equipment
The following equipment is required:
Designation
Article number
Permissible cleaning tools (e.g. cloths,
brushes)
-
Material
The following material is required:
Designation
Article number
Quantity
Neutral cleaning agents
solvent-free, water-soluble, non-flamma-
ble, non-aggressive, no steam, no refrig-
erants, chlorine-free, not strongly acidic,
not strongly alkaline
-
-
KR IONTEC
MA KR IONTEC V4 | Issued: 11.05.2021
www.kuka.com
| 227/344
Maintenance
Summary of Contents for IONTEC KR 20 R3100
Page 14: ...KR IONTEC 14 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Introduction...
Page 166: ...KR IONTEC 166 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Planning...
Page 188: ...KR IONTEC 188 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Start up and recommissioning...
Page 310: ...KR IONTEC 310 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Page 340: ...KR IONTEC 340 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 KUKA Service...