WARNING
Use of the option PURGE is limited to cleaning work. Use during run-
ning operation is precluded in order to prevent the emission of foreign
particles.
11.5.1.1
Installing PURGE option D
Procedure
1. Screw the holder for the pressure regulator and the pressure regulator
together to the bracket using 2 M4x6-8.8 Allen screws
(
>>>
2. Position the bracket with assembly on the base frame and insert and
tighten 2 M6x16-8.8 hexagon bolts. Increase the tightening torque to
the specified value in several stages.
3. Connect compressed air hose to interface A1.
Fig. 11-12: Installing PURGE option D
1
Compressed air supply connection
2
M6x16 hexagon bolt (2x)
3
Bracket
4
Holder for pressure regulator
M4x6 Allen screw (2x)
5
Pressure regulator
6
Robot connection with plastic hose
KR IONTEC
MA KR IONTEC V4 | Issued: 11.05.2021
www.kuka.com
| 333/344
Options
Summary of Contents for IONTEC KR 20 R3100
Page 14: ...KR IONTEC 14 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Introduction...
Page 166: ...KR IONTEC 166 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Planning...
Page 188: ...KR IONTEC 188 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Start up and recommissioning...
Page 310: ...KR IONTEC 310 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...