Fig. 4-32: KR IONTEC, fastening of supplementary load on rotating
column and link arm, R2100
4.4.4
Foundation loads, KR 50 R2100
Foundation loads
The specified forces and moments already include the payload and the in-
ertia force (weight) of the robot.
Foundation loads for floor mounting position
F(v normal)
8203 N
F(v max)
11259 N
F(h normal)
4523 N
F(h max)
9133 N
M(k normal)
8952 Nm
M(k max)
17517 Nm
M(r normal)
5141 Nm
M(r max)
9806 Nm
Foundation loads for ceiling mounting position
F(v normal)
8204 N
F(v max)
11349 N
F(h normal)
4092 N
F(h max)
9242 N
M(k normal)
9703 Nm
M(k max)
18711 Nm