Foundry robots
Overpressure in the
arm
0.03 MPa (0.3 bar) ±10%
Compressed air
Free of oil and water
in accordance with ISO 8573-1:2010 (7:4:4)
Compressed air sup-
ply line
Air line in the cable set
Operating pressure
(PURGE)
max. 0.03 MPa (0.3 bar) ±10%
Air consumption
0.1 m
3
/h
Air line connection
Push-in fitting for hose, 6 mm
Thermal load of the
wrist
10 s/min at 180 °C (453 K)
Resistance
Increased resistance to dust, lubricants, cool-
ants and water vapor.
Special paint finish on
the robot
Special paint finish on the entire robot, and an
additional protective clear coat.
Other ambient condi-
tions
KUKA Deutschland GmbH must be consulted if
the robot is to be used under other ambient
conditions.
The manipulator is designed in such a way that, in accordance with
standard IEC 60529, no water can penetrate into electrical equipment
spaces in normal operation. Water spray and corrosive additives can
nevertheless lead to corrosion (rust) on uncoated parts. In this case, it
is advisable to provide the equipment with corrosion protection. Corro-
sion does not represent a defect as defined by the standard, as long as
it does not have a detrimental effect on the protection rating. The pro-
tection rating is valid in the case of compliance with the specified ambi-
ent conditions.
Ambient conditions
Humidity class (EN 60204)
-
Classification of environmental
conditions (EN 60721-3-3)
-
Ambient temperature
During operation
0 °C to 55 °C (273 K to 328 K)
During storage/transportation
-40 °C to 60 °C (233 K to 333 K)
pH value
7.0 to 9.0
For operation at low temperatures, it may be necessary to warm up the
robot.
During operation in the low-temperature range, frost and condensation
must be avoided, as damage to property may otherwise arise.
KR IONTEC
MA KR IONTEC V4 | Issued: 11.05.2021
www.kuka.com
| 87/344
Technical
data
Summary of Contents for IONTEC KR 20 R3100
Page 14: ...KR IONTEC 14 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Introduction...
Page 166: ...KR IONTEC 166 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Planning...
Page 188: ...KR IONTEC 188 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Start up and recommissioning...
Page 310: ...KR IONTEC 310 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Page 340: ...KR IONTEC 340 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 KUKA Service...