Fig. 4-52: Flange loads
Flange loads during operation
F(a)
1398 N
F(r)
1670 N
M(k)
475 Nm
M(g)
364 Nm
Flange loads in the case of EMERGENCY STOP
F(a)
1937 N
F(r)
3263 N
M(k)
1221 Nm
M(g)
831 Nm
Axial force F(a), radial force F(r), tilting torque M(k), torque about mount-
ing flange M(g)
Supplementary load
The robot can carry supplementary loads. The fastening holes on the arm,
link arm and rotating column are used, for example, for fastening the cov-
ers or external energy supply systems. The fastening holes on the in-line
wrist are exclusively for fastening holders for energy supply systems (e.g.
holders for compressed air hose).
When mounting the supplementary loads, be careful to observe the maxi-
mum permissible total load. The dimensions and positions of the installa-
tion options can be seen in the following diagrams.
KR IONTEC
96/344 |
www.kuka.com
MA KR IONTEC V4 | Issued: 11.05.2021
Technical
data
Summary of Contents for IONTEC KR 20 R3100
Page 14: ...KR IONTEC 14 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Introduction...
Page 166: ...KR IONTEC 166 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Planning...
Page 188: ...KR IONTEC 188 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Start up and recommissioning...
Page 310: ...KR IONTEC 310 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Page 340: ...KR IONTEC 340 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 KUKA Service...