5
Connector panel / Peripheral interfaces (continued)
41 of 70
Hardware R2.2.8 11.98.02 en
5.4
Supply connection X1, service socket X01
L1
L2
L3
N
PE
Incoming supply
3x400V 50/60Hz 25A
3x415V 50/60Hz 25A
only with transformer:
3x440V 50/60Hz 25A
3x480V 50/60Hz 25A
3x500V 50/60Hz 25A
3x550V 50/60Hz 25A
X1
L1
N
PE
Service socket
(Standard version with PEN conductor in the
mains!)
Supply voltage dependent on the mains used;
max. load capacity 6A
X01
Fig. 18 Supply connection X1
Fig. 19 Service socket X01 (optional)
* N--conductor is only required for optional
service socket on 400V mains
PE
1
2
3
4