7
www.BormannTools.com
DC APPLICATION (option)
This usage is applicable to 12V battery charging only.
(a)
Charging instruction for battery
Disconnect the leads for the battery.
Make the battery fluid filler cap loose fully.
Fill distilled water to the upper limit, if the battery fluid is low level.
Measure the specific gravity for the battery fluid by using the hydrometer, and calculate the
charging time in according with the table shown on right side.
The specific gravity for the fully charged battery shall be
within 1.26 to 1.28. It is recommended to confirm every an
hour.
(b)
Connect between the DC output socket and the battery
terminals using the charging leads. The leads shall be
connected making sure of the (+) and (-) polarity.
(c)
The DC circuit protector is to be set to
ON
after confirming
the connection, if the protector is in
OFF
position.
CAUTION:
Be sure the economy control switch is turned
OFF
while charging the battery.
STOPPING THE ENGINE
1.
Turn off the power switch of the electric apparatus or disconnect any electric devices.
2.
Turn the engine switch to
STOP
position.
3.
Turn the fuel cock lever to
OFF
.
4.
Turn the fuel tank cap air vent knob counterclockwise to the
CLOSED
position.
3
2
1
C
Spe
ci
fic
gr
av
ity
20
¡ã
3. 47AH 20HR
2. 35AH 20HR
1. 30AH 20HR
Battery capacity
chargong time Hr
8
10
4
6
2
0
1.06
1.14
1.10
1.22
1.18
1.26
1.30
Aim for specific gravity and charging time
ON
STOP
ENGINE
SWITCH
OFF
CL
OS
E
OP
EN
CLOSE