Laser measurement
With the integrated laser diodes the pipe’s diameter and the width of cracks can be
measured (for more detailed information read the manual of the basic device’s software).
WARNING
Laser radiation hazard!
Laser radiation can harm the eyes. Therefore:
- Do not look into the laser beam.
- Never point the camera at vehicles, individuals or yourself.
Lighting
When the camera is connected to easyTab the LEDs are in flash light mode.
When the camera is connected to proTab the LEDs are in permanent light mode. As soon as
the start of inspection is entered in the software, they automatically switch over to flash light
mode. A manual switch between the two modes is possible at any time. Make sure that the
permanent light mode is active as soon as the camera is outside a closed pipe.
WARNING
Risk of photosensitive seizures!
During operation, the K-70 HD’s LEDs are being flashed. This may cause epileptic
seizures or impair consciousness with light-sensitive individuals and may even affect
people who are not suffering from epilepsy. Therefore, absolutely observe the
following:
•
Never look directly into flashing LEDs
•
Never point flashing LEDs at individuals or motorists, etc.
•
If epilepsy-like symptoms occur, disrupt all work immediately and consult a doctor
•
Always operate the camera with permanent light when it is outside a closed pipe
Measurement of pipe run
K-70 HD features sensors for the measurement of the pipe run. For a ideal measurement the
image has to be centered (for more detailed information read the manual can3D
®
). When the
camera is operated in the finding mode, the measurement is interrupted. This option is only
available with proTab.
END OF WORK
Make sure that the LEDs are in permanent light mode and remove the camera from the pipe.
Switch the camera off via the basic device (for more detailed information read the manual of
the basic device’s software). Disconnect camera and rod (see
Dismounting
) and attach the
protective cap. Clean the camera (see
Cleaning
).