Model A
Page 32 of 47
4.4 operating procedure
1. Switch on the main power and open the main air source.
2. Turn the red power switch on the control box into “on”, then turn the power key on the control
box into “on”, then press “power start” and electrify the whole machine.
3. Check if the air source is 5KG or not, and combine the three parts, i.e. water filter cup, oil cup
and pressure gauge. Press the bottom of the water filter cup to perform daily drainage. (Note if
the oil cup has oil or not)
4. Check if the tailstock spindle works properly or not, the left-right movement smooth or not, all
sensors normal or not, manual blade feeding right or not, the main shaft start proper or not,
and angle movement smooth or not.
5. Install the circular blade on the blade holder, and check if the blade edge has burr, notch or is
blunt. Lock the blade with special wrench, and fasten the circular blade axis with fixed bolt.
Rectify the circular blade origin point with special fixture (first loosen the screw at the bottom
of the blade holder, then move the blade holder as backward as possible with adjusting handle,
then set the fixture on the copper part of the rotating plate, and align fixture surface notch with
circular blade at 90°angle, then move the blade holder forward with adjusting handle, and then
fix the screw at the bottom of the blade holder, and then move the fixture to the circular blade
tip with only 0.1mm distance from fixture surface so that the fixture would not touch the blade
edge and damage the circular blade). Rotate 90°with visual measurement to parallel the fixture
surface with circular blade surface then take out the fixture, and fix the safety stop screw on
sides of the drip pan.
6. Stick the magnetic base dial indicator to the drip pan. Align the dial indicator head with the
circular blade slope to check the blade (First take out the fixed bolt of the circular blade axis
so that the circular blade would freely rotate. Then visually measure the number on the dial
indicator surface when the blade rotates. And then adjust front and back blade clamp screws
with wrench. When the circular blade surface numbers are within 0.05mm, then fix all screws
on the clamp).
Summary of Contents for FR-1300A
Page 5: ...Model A Page 3 of 47 1 3 safety position drawing...
Page 11: ...Model A Page 9 of 47 2 5 machine dimension...
Page 15: ...Model A Page 13 of 47 3 4 Installation method Model FR 1300AB Model FR 1600AB...
Page 18: ...Model A Page 16 of 47 3 7 Gas circuit...
Page 20: ...Model A Page 18 of 47 4 Operation 4 1 operating position Model FR1300AB FR 1600AB...