Ventilator capacity
Watt
2x21
2x21
A Width
mm
600
680
B Depth
mm
910
1000
C Height
mm
1355
1630
D Height of exhaust pipes
mm
1170
1430
E Exhaust pipe diameter
mm
180
200 (seitl.180)
Weight
kg
320
420
Water content
Liter
90
180
Gas content (without feeder hatch)
l
85
118
Water resistance
mWs
0,08
0,13
Draught requirement
1
Pa
10
10
Necessary conveyance pressure
Pa
18
18
Exhaust mass current
2
kg/s
0,022
0,035
- when heating
kg/s
0,045
0,070
Exhaust gas temperature nominal
o
C
170
180
Exhaust gas temp. when heating
o
C
150
150
CO2 at nominal output
%
13,5
15
Particulate emissions (13% O2)
mg/m
3
9
18
Total efficiency
%
91
92
Stand-by loss
Watt
55
65
Electrical connections
240V AC,10A,50Hz
240V AC,10A,50Hz
1
also when heating
2
All boilers with a FD fan are equipped as standard with a draught regulator.
25
Summary of Contents for BT 2030
Page 1: ...Operating manual Wood gasifier boiler BT 2030 and BT 2050 ...