Type
PK10
PK15
PK20
Rated heat output
kW
10
14,9
20
Burner output, max.
kW
13
17
23
Burner output, min.
kW
7
10
15
Burner output, recommended
kW
10
15
20
Fuel
Wood pellets
1
Permissible boiler temperature
o
C
95
95
95
Achievable boiler temp.
o
C
90
90
90
Permissible operating gauge pressure
bar
3
3
3
Weight
kg
157
207
273
Water capacity
Litre
47
60
97
Gas capacity
Litre
44
82
116
Ash pan
Liter
9
12
24
Capacity, internal receptacle, burner
Litre
3
3
3
Water-side resistance
Pa
400
400
400
Necessary chimney draft
Pa
10
10
10
Maximum chimney draft
Pa
18
18
18
Exhaust gas mass flow rate at rated load
kg/s
0,009
0,0135
0,018
Exhaust temperature
o
C
130
130
130
CO
2
%
12
12
12
Exhaust gas connection diameter
mm
110
110
130
Efficiency
%
90,2
91
92,3
Electrical supply
230V AC, 10A, 50Hz
Burner
80W, 230V, 50Hz
Fuses
6A automatic circuit breaker
6A high-speed fuse for the heating coil
External conveyor screw
single phase 230V AC, 50 Hz, 250W, 2.4A
capacitor 14
µ
F
three-phase motor should be used for conveyor
screws that are greater than 3m in length
External diameter of conveyor screw: 90 mm
Overall length of conveyor screw with motor: 3250 mm
Combustion fan
Speed monitoring achieved by means
of speed control system
Height H
mm
927
1202
1228
Width B
2
mm
537
560
637
Depth, excl. burner T
mm
653
679
782
Depth incl. burner TB
mm
1012
1055
1141
In acc. with standard DIN EN 303-5
x
x
x
26
Summary of Contents for PK 10
Page 1: ...Installation manual pellet boiler PK 10 PK 15 and PK 20 May 4 2009 ...
Page 25: ...4 Technical data Figure 26 The PK pellet boiler Figure 27 Connecting dimensions 25 ...
Page 28: ...Figure 29 Wiring diagram for pellet boiler 28 ...
Page 29: ...Figure 30 Wiring diagram for PK 230V conveyor screw drive 29 ...
Page 30: ...Figure 31 Wiring diagram for PK 400V conveyor screw drive 30 ...
Page 31: ...Personal notes 31 ...
Page 32: ... ...