Routine maintenance to be performed
Dust bag (for the user)
As an alternative to a fabric bag a remote control
industrial vacuum cleaner with tube with maximum length
of 10 metres may be used.
Graphite brushes (for the user)
The motor has two graphite brushes that must be checked every six months or after 400 hours of
operation. The check the brushes carry out the following procedure:
1. Remove the screws on the side motor covers with a screwdriver.
2. Remove the cover.
3. Remove the wire terminal screw.
4. Remove the brush complete with spring.
5. Check the brushes. If one of the brushes is shorter by 7 mm replace both brushes.
WARNING
When fitting new brushes ensure they are installed correctly before replacing the cover.