14
Service Manual
For internal use only
7.5
Double thermostat
The double thermostat prevents the appliance from becoming overheated.
It is located under the heating element.
Technical data:
•
220/240V
~
•
Opens at 210°C
7.6
Thermistor
The thermistor keeps the vent flap closed while the oven is in operation.
Technical data:
•
220/240V
~
•
5W
•
1k
Ω
7.7
Door switch
The door switch enables the cooking cycle to be changed when the door
is open.
Door open:
switch off
Door closed:
switch on
7.8
Cross-flow fan
The cross-flow fan guarantees consistent ventilation of the oven during the
cooking process and enables steam to leave the oven during the final
three minutes of a cooking cycle.