Replacing a halogen lamp
Caution! Only replace defective halogen lamps with lamps of the
same type.
–
Undo the screws of the spotlight
holder.
–
Carefully pull the halogen spotlight
downwards out of the socket.
–
Insert a new spotlight (20 Watt)
into the socket with slight
pressure.
–
Screw the holder tight again.
What to do in case of trouble
Repairs should only be carried out by an authorised technician.
Before carrying out any repair work, the appliance must bediscon-
nected from the power supply by pulling out the mains plug or
switching off the household fuse.
First check whether there has been any case of maloperation. You can deal
with some problems that occur yourself.
Problem
Cause
Remedy
The cooker hood
cannot be switched
off.
Defective electronic
component.
Disconnect the mains plug
an call Customer Service.
Halogen lighting not
working.
Defective lamp.
Replace lamp.
Light-emitting diode
not working.
Defective light-emitting
diode.
Call Customer Service.
Power of the cooker
hood becoming
weaker.
Filter has not been
changed in proper time.
Change filter.
Rating label
The rating label will become visible when you have removed the fat filter or
the activated charcoal filter. In case you have to consult Customer Service,
please make a note of the following data on the rating label before or while
installing the cooker hood:
Serial number:
Model designation:
Installation
Danger! The cooker hood may only be installed and connected by
an authorised technician.
Observe the safety notes on page 15!
Caution! Do not carry the hood by holding the railing of a glass
plate.
The fitter requires at least one helper for some operations.
Scope of delivery
Inner frame, chimney panelling, drilling template, attachment material
Hood with motor, hood glass, remote control
Glass shelf
IKDEM 908.1:
With the hood version with an external motor, the motor is
supplied separately.
Installation preconditions
Please also observe the notes on fume extraction on page 22.
The island canopy hood IKD 908.1/IKDEM 908.1 can only be connected as
an extractor; recirculation mode is not possible.
Ceilings suitable for fastening
Caution! The ceiling structure must be suitable for the total weight
of the island canopy hood.
The hood is attached to the room ceiling in such a way that there is a
distance of at least 650 mm between the cooking surface and the hood
lower edge.
The fitter is always responsible for selecting the correct fastening material.
The fastening method must be suitable for the weight of the island canopy
hood and the lever forces which occur when side pressure is applied to the
appliance when installed.
The enclosed dowels and screws are suitable for ceilings made of
perforated bricks or concrete bricks which are 20 mm thick.
For solid concrete ceilings you must use special concrete dowels from a
specialist store.
For solid wooden ceilings you must use wood screws of sufficient thick-
ness and length.
Electric connection
The hood is fitted with a normal mains plug and there should therefore be a
socket outlet (230V AC) near the point of installation.
Danger! The hood must be disconnected from the mains for all in-
stallation and maintenance work. If the mains plug can no longer
be reached after installation, you must switch off the relevant
household fuse.
18
IKD 908.1