20

GB

RECIRCULATION VERSION AIR OUTLET

• Insert reducer flange 9 on the extractor outlet.
• Push fit the extension piece 14 onto the flange.
• Push fit connector 15  onto the extension piece.
• Insert extension piece/connector 14.1 laterally on

connector 15, ensuring that the outlet is in line
with the chimney intake.

Flue assembly - Mounting the hood body

• Position the upper chimney stack and fix the top of it to

the frame using 2 of the screws removed as above.

• Insert the lower chimney stack into the frame, holding

it in place with adhesive tape in the area separating the
lower chimney stack from the upper one.

Recirculation version
• Make sure that the outlet of the extension piece  14.1 is

horizontally and vertically aligned with the chimney
outlet.

• If this is not the case, remove the lower Chimney Stack

and adjust the position of Extension 14; replace the
elements as described above.

Before fixing the Hood Canopy to the Frame:
• Remove the grease filters  from the hood body;
• Remove any activated charcoal filters.
• From below, use the 4 screws 12f provided to fix the hood

body to the frame.

• Remove the adhesive tape fixed to the lower chimney

stack as above, and rest the lower chimney stack against
the hood canopy.

• For the Recirculation Version, fit the directional grill 8

into the housing provided. Also make sure that it is
properly fitted into connector 15.

12f

8b

15
14.1

14

9

Summary of Contents for IKDEM 976.2GE-84

Page 1: ...Bedienungsanleitung Instructions Booklet Mode d emploi Libretto Istruzioni Gebruiksaanwijzing Manual de instrucciones Manual de Instruções NL IT FR GB DE IKDEM 976 2GE 84 PT ES ...

Page 2: ...recommendations contained in this Instruction Manual your appliance will give you constant high performan ce and will remain efficient for many years to come RECOMMENDATIONSAND SUGGESTIONS 15 CHARACTERISTICS 16 INSTALLATION 18 USE 21 MAINTENANCE 22 ...

Page 3: ...nt degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Never lea...

Page 4: ...16 GB CHARACTERISTICS Dimensions 650 min 732 435 898 72 500 min 790 max 1170 790 90 135 500 340 ...

Page 5: ... Upper frame 7 1b 1 Lower frame 8 1 Air Outlet Grill 9 1 Reducer Flange ø 150 120 mm 14 1 Hood Body Air Outlet Extension Piece consisting of two Half Shells 14 1 1 Air Outlet Connection Extension 15 1 Air Outlet Connection 24 1 Junction box 25 2 Pipe clamps Ref Q ty Installation Components 11 4 Wall Plugs ø 10 12c 4 Screws 2 9 x 6 5 12e 4 Screws 2 9 x 9 5 12f 4 Screws M6 x 10 12g 4 Screws M6 x 80 ...

Page 6: ...lings with wall thickness of 20 mm drill ø 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill ø 7 mm For the power supply cable feed drill ø 10 mm For the air outlet DuctedVersion drill according to the diameter of the external air exhaust duct connection Insert two screws of the following type crossing them and l...

Page 7: ... and fasten the other two screws provided before locking the screws completely it is possible to adjust the frame by turning it making sure that the screws do not come out of their housing in the adjustment slot The Frame must be securely fastened so as to support both the weight of the Hood and the stress caused by occasional axial pressure against the fittedAppliance After fixing make sure that ...

Page 8: ...k from the upper one Recirculation version Make sure that the outlet of the extension piece 14 1 is horizontally and vertically aligned with the chimney outlet If this is not the case remove the lower Chimney Stack and adjust the position of Extension 14 replace the elements as described above Before fixing the Hood Canopy to the Frame Remove the grease filters from the hood body Remove any activa...

Page 9: ...version fit the activated carbon odour filter Replace the grease filters USE Control Panel The hood can be switched on pushing directly onto the requested speed without firstly having to select 0 1 button KEY LED FUNCTIONS L 0 1 Light Turns lighting on and off T1 0 1 Motor on First speed When pressed for about 2 seconds the motor is switched off T2 Speed on Second speed T3 Speed on Third speed T4 ...

Page 10: ... carbon zinc alkaline batteries of the standard LR03 AAA type Do not place the remote control near to heat sources Used batteries must be disposed of in the proper manner MAINTENANCE Grease filters CLEANING METAL SELF SUPPORTING GREASE FILTERS Alarm signal reset Switch off the lights and extractor motor Press button T3 for at least 3 seconds until the leds start to flash Cleaning the filters The f...

Page 11: ...on Hoods the Filter saturation alarm can be enabled on installation or at a later date Turn the Lights and the suction Motor off Disconnect the Hood using the Main switch or the double pole switch on the mains power supply Restore the connection by pressing and holding T1 Release the button All five LEDs are turned on Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation LED flashes...