This  canopy  hood  is  designed  to  be  fixed  to  any  rigid  vertical  surface,  over  a  gas  or
electric hotplate and can be used either in the extraction mode (ducted to the outside) or
in the recirculation mode (internal recycling).

Safety  warnings

• Before  commencing  the  installation,  consideration  should  be  given  to  the  difficulties

to  be  found  during  installation  and  to  the  bulky  weight  of  the  hood.  The  installation
work  must  be  undertaken  by  a  qualified  and  competent  person  in  conformity  to  the
rules  concerning  the  evacuation  of  contaminated  air.  The  manufacturer  disclaims  all
liability  for  any  damage  or  injury  caused  as  a  result  of  not  following  the  instructions
for  installation  contained  in  the  following  text.

• When used in the extraction mode the cooker hood ducting must not be connected to

a flue which is used for exhausting fumes from appliances supplied with energy other
than  electric  such  as  a  central  heating  flue  or  water  heating  flue.

• When istalled, the hood must be positioned at least 65 cm above a cooking appliance.
• Never  do  flambé  cooking  under  this  cooker  hood.
• Never leave frying pans unattended during use as overheated fats and oils may catch

fire.

• If  the  room  where  the  cooker  hood  is  to  be  used  contains  a  fuel  burning  appliance

such as a central heating boiler then this must be of the room sealed or balanced flue
type.  If  other  types  of  flue  or  appliance  are  fitted  ensure  that  there  is  an  adequate
supply  of  air  into  the  room.  When  the  cooker  hood  is  used  in  conjunction  with  other
appliances supplied with energy other than electric, the negative pressure in the room
must  not  exceed  0,04  mbar  to  prevent  fumes  being  drawn  back  into  the  room  by  the
cooker  hood.

Components

The hood comprises the following (

fig.1

 ):

• No.1 canopy 

C

 complete with controls, lighting and ventilator unit

• No.1 telescopic chimney, comprising:

No.1 upper chimney element 

S

No.1 lower chimney element 

I

• No.2 directional grills 

G

• No.1 recirculation spigot 

R

• No.2 additional side recirculation spigots 

P1

• No.1 bag containing:

No.2 brackets 

2

 to fix the chimney, screws, rawl plugs and documents.

• No.1 splashback 

B

 (optional)

Installation  instructions

For easy installation, proceed as follows:

• Fitting the wall brackets and Splashback
• Fixing the canopy
• Electrical connection and working test
• Ducting or Recirculation fitting
• Fitting the telescopic chimney

Summary of Contents for KD 6500

Page 1: ...KD 6600 KD 9600 DE GB Bedienungsanleitung Instructions Booklet F Mode d emploi NL Gebruiksaanwijzing I Libretto Istruzioni Manual de Instrucciones Bruksanvisning Manual de Instruções GR E P S ...

Page 2: ...this cooker hood Never leave frying pans unattended during use as overheated fats and oils may catch fire If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then this must be of the room sealed or balanced flue type If other types of flue or appliance are fitted ensure that there is an adequate supply of air into the room When the coo...

Page 3: ...canopy Small adjustments can be made using the hood adjustment screws see Fitting the canopy The hood should have a maximum excursion of 20 mm Splashback optional When a splashback is to be fitted the distance between the hood and the cooking appliances will be determined by the height of the splashback B and whether or not there is a raised back on the worktop The splashback is to be installed be...

Page 4: ... fan outlet pushing it downwards and fit spigot R in a similar manner make sure that the two additional side recirculation spigots P1 are fitted to spigot R Make sure that the height of the assembly R T corresponds to the height of the chimney outlet fig 6 Fit the activated charcoal filters inside the canopy see paragraph on Maintenance Do not fit the venting grilles until after the chimney has be...

Page 5: ...able to deal with maximum vapour emission this turns off automatically ten minutes after starting operation It can be disabled by pressing the button T5 Press T5 for approximately 3 seconds to enable the Power function maximum suction power which is indicated by flashing of the LED over the button This function will be revert to intensive speed after 5 minutes or when T5 is pressed again MAINTENAN...

Page 6: ...rated filters alarm must be enabled as indicated below Turn off the lights and the suction motor Press and hold the T4 button for at least 10 seconds until the LEDs start to flash Note the number of flashes 2 flashes of the LED Activated charcoal filter saturation alarm ENABLED 1 flash of the LED Activated charcoal filter saturation alarm DISABLED Resetting the alarm signal To turn the alarm signa...

Page 7: ...1 2 B R P1 2 G G S C I 232 260 1 1 2 260 1 1 20 X H min 650 d 970 min Abb 2 b a ...

Page 8: ...S1 S1 S1 S1 1 1 1 1 1 1 R P1 T G S A18_714_03 R P1 T G S A18_714_03 6 4 3 5 8 G 2 S I 2 C 7 ...

Page 9: ...T1 T2 T3 T4 T5 9 10 11 12 ...

Reviews: