Electrical  connection  and  working  test

• Before  connecting  to  the  mains  supply  ensure  that  the  mains  voltage  corresponds

with  the  voltage  on  the  rating  plate  inside  the  hood.

• Connect  the  cooker  hood  to  the  mains  via  a  double  pole  switch  which  has  3  mm

clearance  between  the  contacts.

• The  appliance  must  be  earthed.
• Once  the  electrical  connection  has  been  completed,  check  that  worktop  illumination,

motor  and  speed  work  properly.

Ducting  or  Recirculation  fitting

• Ducting  fitting

• The hood can be ducted to the outside using either rigid or flexible ducting Ø 150 mm,

the choice of which is left to the installer (

fig.5

).

• If the hood is supplied with the activated charcoal filters fitted, the filters should be removed

(see paragraph on Maintenance).

• Recirculation  fitting

• The filtered air is returned to the room through the two plastic side grills G on the upper

chimney element 

S

 .

• Connect the pipe 

T

 to the round fan outlet, pushing it downwards, and fit spigot 

R

 in a

similar manner (make sure that the two additional side recirculation spigots 

P1

 are fitted

to spigot 

R

). Make sure that the height of the assembly 

R

 + 

T

 corresponds to the height

of the chimney outlet.(

fig.6

).

• Fit the activated charcoal filters inside the canopy (see paragraph on 

Maintenance

 ). Do

not fit the venting grilles until after the chimney has been installed.

Fitting  the  telescopic  chimney

• To fit the upper section 

S

 first expand the two side pieces slightly, hook them behind the

brackets 

2

 and close them together again until they touch. Fix the upper section 

S

 to the

brackets 

2

 using four of the screws provided in the bag of accessories (

fig.7

).

• Fit the lower section 

I

 as above, between the upper section 

S

 and the canopy 

C

.

• Chimney with venting grilles: Snap the venting grilles into position in the apertures located

on  the  chimney  section,  so  that  the  symbol 

  is  turned  upwards  and  the  symbol 

faces forwards. Also, when the hood is used in recirculation mode, ensure that the grilles
are properly secured to the inside of the recirculation spigot 

R

 (

fig.8

).

Summary of Contents for KD 6500

Page 1: ...KD 6600 KD 9600 DE GB Bedienungsanleitung Instructions Booklet F Mode d emploi NL Gebruiksaanwijzing I Libretto Istruzioni Manual de Instrucciones Bruksanvisning Manual de Instruções GR E P S ...

Page 2: ...this cooker hood Never leave frying pans unattended during use as overheated fats and oils may catch fire If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then this must be of the room sealed or balanced flue type If other types of flue or appliance are fitted ensure that there is an adequate supply of air into the room When the coo...

Page 3: ...canopy Small adjustments can be made using the hood adjustment screws see Fitting the canopy The hood should have a maximum excursion of 20 mm Splashback optional When a splashback is to be fitted the distance between the hood and the cooking appliances will be determined by the height of the splashback B and whether or not there is a raised back on the worktop The splashback is to be installed be...

Page 4: ... fan outlet pushing it downwards and fit spigot R in a similar manner make sure that the two additional side recirculation spigots P1 are fitted to spigot R Make sure that the height of the assembly R T corresponds to the height of the chimney outlet fig 6 Fit the activated charcoal filters inside the canopy see paragraph on Maintenance Do not fit the venting grilles until after the chimney has be...

Page 5: ...able to deal with maximum vapour emission this turns off automatically ten minutes after starting operation It can be disabled by pressing the button T5 Press T5 for approximately 3 seconds to enable the Power function maximum suction power which is indicated by flashing of the LED over the button This function will be revert to intensive speed after 5 minutes or when T5 is pressed again MAINTENAN...

Page 6: ...rated filters alarm must be enabled as indicated below Turn off the lights and the suction motor Press and hold the T4 button for at least 10 seconds until the LEDs start to flash Note the number of flashes 2 flashes of the LED Activated charcoal filter saturation alarm ENABLED 1 flash of the LED Activated charcoal filter saturation alarm DISABLED Resetting the alarm signal To turn the alarm signa...

Page 7: ...1 2 B R P1 2 G G S C I 232 260 1 1 2 260 1 1 20 X H min 650 d 970 min Abb 2 b a ...

Page 8: ...S1 S1 S1 S1 1 1 1 1 1 1 R P1 T G S A18_714_03 R P1 T G S A18_714_03 6 4 3 5 8 G 2 S I 2 C 7 ...

Page 9: ...T1 T2 T3 T4 T5 9 10 11 12 ...

Reviews: