background image

17

GB

OPERATION

Safety  warnings

Before  carring  out  any  kind  of  maintenance  or  cleaning,  disconnect  the  hood  from  the  mains  supply.

The grease filters and the charcoal filter should be cleaned or replaced as recommended by the manufacturer
or  more  frequently  if  the  hood  is  used  consistently  over  4  hours  per  day.

When using a gas hob in connection with the cooker hood never leave the burners of  the hob uncovered while
the  hood  is  in  use  or  when  the  pans  have  been  removed.  Switch  off  the  gas  before  removing  the  pan,  or  for
just  short  periods  and  never  leave  the  hob  unattended.

Always  ensure  that  the  flame  is  kept  at  the  correct  intensity  to  prevent  the  flame  from

licking  round  from

the  bottom  of  the  pan;  this  will  save  energy  and  will  avoid  a  dangerous  concentration  of  heat.

Always  ensure  that  the  appliance  is  used  in  accordance  with  the  manufacturer’s
instructions  for  the  removal  of  contaminated  air  and  odours  during  cooking.

Instruction  for  Use

Control Panel (fig. 9)

The layout of the control panel is as follows:
Button  

T1

= Turns the lighting system on and off

Button  

T2

= Turns the motor on and off

Button  

T3

= Decreases the working speed

Button  

T4

= Increases the working speed

Button  

T5

= Intensive speed with timed stoppage. Suitable to deal with maximum vapour

emission, this turns off automatically ten minutes after starting operation.
It can be disabled by pressing the button 

T5

.Press 

T5

 for approximately 3

seconds to enable the 

Power

 function (maximum suction power), which is

indicated by flashing of the LED over the button. This function will be revert
to intensive speed after 5 minutes or when 

T5

 is pressed again.

MAINTENANCE

Constant maintenance guarantees proper operation and longterm reliability.  Particular
attention should be paid to the metal grease filters and, for recirculation hoods only, to
the  activated  charcoal  filters.  The  appliance  is  equipped  with  a  system  that  indicates
automatically when it is time to carry out maintenance operations.

Metal  grease  filters

• Cleaning

These  filters  must  be  washed  when  LED 

Filters 

starts,  or  at  the  most  once  every  2

months, using a normal household detergent; their compact size also enables them to
be washed in a dishwasher.

• Removing the filters

Remove one filter at a time, pulling and turning the handle in an anticlockwise direction –
see 

fig.10

. Replace by repeating the same operations in reverse order, making sure that

the handle is turned to face the outside.

• Enabling the alarm signal

The hood is already set up to trigger an alarm indicating saturation of the metal grease
filters, so this function does not need to be enabled.

• Resetting the alarm signal

To turn the alarm signal off, proceed as follows:

Summary of Contents for KD 6500

Page 1: ...KD 6600 KD 9600 DE GB Bedienungsanleitung Instructions Booklet F Mode d emploi NL Gebruiksaanwijzing I Libretto Istruzioni Manual de Instrucciones Bruksanvisning Manual de Instruções GR E P S ...

Page 2: ...this cooker hood Never leave frying pans unattended during use as overheated fats and oils may catch fire If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then this must be of the room sealed or balanced flue type If other types of flue or appliance are fitted ensure that there is an adequate supply of air into the room When the coo...

Page 3: ...canopy Small adjustments can be made using the hood adjustment screws see Fitting the canopy The hood should have a maximum excursion of 20 mm Splashback optional When a splashback is to be fitted the distance between the hood and the cooking appliances will be determined by the height of the splashback B and whether or not there is a raised back on the worktop The splashback is to be installed be...

Page 4: ... fan outlet pushing it downwards and fit spigot R in a similar manner make sure that the two additional side recirculation spigots P1 are fitted to spigot R Make sure that the height of the assembly R T corresponds to the height of the chimney outlet fig 6 Fit the activated charcoal filters inside the canopy see paragraph on Maintenance Do not fit the venting grilles until after the chimney has be...

Page 5: ...able to deal with maximum vapour emission this turns off automatically ten minutes after starting operation It can be disabled by pressing the button T5 Press T5 for approximately 3 seconds to enable the Power function maximum suction power which is indicated by flashing of the LED over the button This function will be revert to intensive speed after 5 minutes or when T5 is pressed again MAINTENAN...

Page 6: ...rated filters alarm must be enabled as indicated below Turn off the lights and the suction motor Press and hold the T4 button for at least 10 seconds until the LEDs start to flash Note the number of flashes 2 flashes of the LED Activated charcoal filter saturation alarm ENABLED 1 flash of the LED Activated charcoal filter saturation alarm DISABLED Resetting the alarm signal To turn the alarm signa...

Page 7: ...1 2 B R P1 2 G G S C I 232 260 1 1 2 260 1 1 20 X H min 650 d 970 min Abb 2 b a ...

Page 8: ...S1 S1 S1 S1 1 1 1 1 1 1 R P1 T G S A18_714_03 R P1 T G S A18_714_03 6 4 3 5 8 G 2 S I 2 C 7 ...

Page 9: ...T1 T2 T3 T4 T5 9 10 11 12 ...